1
0
Fork 0

monitor: improve heuristic to determine display output name

Under some circumstances, for example when the display controller driver
doesn't report back the correct EDID, or under VirtualBox, Mutter
returns suboptimal strings for an output display name, leading to funny
labels like 'Unknown 0"', or '(null) 0"' in the Settings panel.

This commit improves our heuristic in three ways:
- we now avoid putting inches in the display name if either dimension is
  zero
- we use the vendor name in case we're not able to lookup its PnP id
  from the database. Previously we would have passed over '(null)'
- as a special edge-case, when neither inches nor vendor are known, we
  use the string 'Unknown Display'

Finally, we make the combined vendor + inches string translatable, as
different languages might want to move the size part of the string to a
position different than the end.

https://bugzilla.gnome.org/show_bug.cgi?id=721674
This commit is contained in:
Cosimo Cecchi 2014-01-06 18:26:03 -08:00
parent 1d04ea62ba
commit 477acddf64

View file

@ -691,46 +691,61 @@ static char *
make_display_name (MetaMonitorManager *manager,
MetaOutput *output)
{
char *inches = NULL;
char *vendor_name = NULL;
char *ret;
gboolean is_unknown = FALSE;
if (g_str_has_prefix (output->name, "LVDS") ||
g_str_has_prefix (output->name, "eDP"))
return g_strdup (_("Built-in display"));
{
ret = g_strdup (_("Built-in display"));
goto out;
}
if (output->width_mm != -1 && output->height_mm != -1)
if (output->width_mm > 0 && output->height_mm > 0)
{
double d = sqrt (output->width_mm * output->width_mm +
output->height_mm * output->height_mm);
char *inches = diagonal_to_str (d / 25.4);
char *vendor_name;
char *ret;
inches = diagonal_to_str (d / 25.4);
}
if (g_strcmp0 (output->vendor, "unknown") != 0)
{
if (!manager->pnp_ids)
manager->pnp_ids = gnome_pnp_ids_new ();
if (g_strcmp0 (output->vendor, "unknown") != 0)
{
if (!manager->pnp_ids)
manager->pnp_ids = gnome_pnp_ids_new ();
vendor_name = gnome_pnp_ids_get_pnp_id (manager->pnp_ids,
output->vendor);
vendor_name = gnome_pnp_ids_get_pnp_id (manager->pnp_ids,
output->vendor);
ret = g_strdup_printf ("%s %s", vendor_name, inches);
g_free (vendor_name);
}
else
{
/* TRANSLATORS: this is a monitor name (in case we don't know
the vendor), it's Unknown followed by a size in inches,
like 'Unknown 15"'
*/
ret = g_strdup_printf (_("Unknown %s"), inches);
}
g_free (inches);
return ret;
if (!vendor_name)
vendor_name = g_strdup (output->vendor);
}
else
{
return g_strdup (output->vendor);
if (inches != NULL)
vendor_name = g_strdup (_("Unknown"));
else
vendor_name = g_strdup (_("Unknown Display"));
}
if (inches != NULL)
{
/* TRANSLATORS: this is a monitor vendor name, followed by a
* size in inches, like 'Dell 15"'
*/
ret = g_strdup_printf (_("%s %s"), vendor_name, inches);
}
else
{
ret = g_strdup (vendor_name);
}
out:
g_free (inches);
g_free (vendor_name);
return ret;
}
static gboolean