1
0
Fork 0
Commit graph

21 commits

Author SHA1 Message Date
Thomas Hellstrom
103c88bd72 mutter/wayland: Have the native backend read drm layout properties
Read the drm layout properties suggested_X, suggested_Y and
hotplug_mode_update and transfer them to the meta layer.

Signed-off-by: Thomas Hellstrom <thellstrom@vmware.com>

https://bugzilla.gnome.org/show_bug.cgi?id=750363
2015-06-03 13:28:19 -07:00
Dave Airlie
6a77d9722a backend: add output tile info retrieval.
this just adds backend support for retrieving the tile
information from X11 (randr 1.5) and native backends.

It stores the tiling information into the output struct.
2015-06-01 09:38:13 -07:00
Rui Matos
7eca43cec9 monitor-manager-kms: Avoid a couple of potential crashes
The drm API can return NULL and we could end up using uninitialized
memory if the driver private struct isn't cleared.
2015-04-28 18:00:45 +02:00
Rui Matos
9060190555 monitor-manager-kms: Read crtc props after determining the crtc ID
Otherwise we can't read the properties.
2015-04-28 18:00:44 +02:00
Jasper St. Pierre
48bf807430 monitor-manager-kms: Add support for underscan 2015-04-27 17:58:38 -07:00
Rui Matos
43058a3698 monitor-manager-kms: Tell cogl to ignore CRTCs when DPMS isn't ON
Otherwise cogl will try to page flip and fail.

https://bugzilla.gnome.org/show_bug.cgi?id=746098
2015-03-16 16:32:56 +01:00
Rui Matos
9c6e6ea381 monitor-manager-kms: Fix a crash getting a crtc-less output's scale
https://bugzilla.gnome.org/show_bug.cgi?id=745476
2015-03-02 18:48:56 +01:00
Rui Matos
db9645fcb3 monitor-manager-kms: Cope with non-existent connectors and encoders
DRM objects like connectors and encoders might change at any time, in
particular they might become invalid between drmModeGetResources() and
getting the actual objects in which case they'll be NULL. Be defensive
against that.

Note that, if this happens, we should get another udev event soon
which will cause us to update our state.

https://bugzilla.gnome.org/show_bug.cgi?id=745476
2015-03-02 18:48:55 +01:00
Rui Matos
6af48d75a4 monitor-manager-kms: Don't store a list of encoders
It's not needed outside of read_current() and current_encoder is
totally unused.

https://bugzilla.gnome.org/show_bug.cgi?id=745476
2015-03-02 18:48:53 +01:00
Jasper St. Pierre
78d8525699 backends/native: Calculate the output scale in here
It makes more sense as a backend thing, not a frontend thing.
2015-02-26 00:13:28 -08:00
Rui Matos
ad90b7dd2f monitor-manager: Initialize MetaOutput even when we can't get the EDID
Otherwise we'll crash later when building a MetaConfiguration.

https://bugzilla.gnome.org/show_bug.cgi?id=743412
2015-01-27 14:42:45 +01:00
Carlos Garnacho
625d3de2ee backends: Make KMS EDID information equal to X11's
EDID parsing has been refactored to a common meta_output_parse_edid()
function, which ensures the extracted information is the same on both KMS
and X11 backend, so it can be used consistently on eg. settings values.

https://bugzilla.gnome.org/show_bug.cgi?id=742882
2015-01-14 12:16:18 +01:00
Jasper St. Pierre
d514e8ab41 monitor-manager: Add a connector-type property
This is so gnome-settings-daemon
2014-12-29 16:30:54 -08:00
Jasper St. Pierre
2f7843b295 monitor-manager-kms: Fix some minor style issues
Spotted by Dave Airlie <airlied@redhat.com>
2014-12-15 14:15:46 -08:00
Jonathon Jongsma
f6f5f624d4 monitor-manager: Add support for suggested position for outputs
In recent versions of the QXL driver, it may set "suggested X|Y" connector
properties. These properties are used to indicate the position at which
multiple displays should be aligned.  If all outputs have a suggested position,
the displays are arranged according to these positions, otherwise we fall back
to the default configuration.

At the moment, we trust that the driver has chosen sane values for the
suggested position.
2014-11-20 12:24:16 -06:00
Rui Matos
b3821c4f90 monitor-manager: Don't try to match the outputs on hotplug
meta_monitor_config_match_current() only matches the number of outputs
and if the output connector, vendor, product and serial match.

In the X backend, this means that we can't use it to bypass doing any
work because it won't detect cases where we actually want to update
ourselves like e.g. an output being turned off either by us or by
another X client (e.g. xrandr).

In the native backend, unlike the xrandr backend, we only get called
on real hotplug events and thus should always trigger the common
hotplug code to (possibly) apply a new mode so the check is pointless
anyway.

https://bugzilla.gnome.org/show_bug.cgi?id=738630
2014-10-16 20:39:16 +02:00
Jasper St. Pierre
722d4c6c17 native: Implement monitor hotplug in the native backend
Use gudev to notice when new monitors are hotplugged, and when they are,
update the configuration.
2014-10-14 13:56:48 -07:00
Jasper St. Pierre
eb952819c2 monitor: Don't use wl_output_transform in our APIs
Invent our own API so we can build without Wayland headers.
2014-07-13 11:35:01 -04:00
Jasper St. Pierre
af135c0b0b monitor-manager: Rename output_id to winsys_id
The output_id is more of an opaque identifier for the monitor, based on
its underlying ID from the windowing system. Since we also use the term
"output_id" for the output's index, rename our use of the opaque cookie
"output_id" to "winsys_id".
2014-07-01 13:24:34 -04:00
Jasper St. Pierre
25a16c3379 Remove trailing whitespace 2014-05-02 09:34:48 -04:00
Jasper St. Pierre
bce1d5117b Start creating different subdirectories for each backend 2014-03-31 23:44:47 -04:00
Renamed from src/backends/meta-monitor-manager-kms.c (Browse further)