1
0
Fork 0
Commit graph

26 commits

Author SHA1 Message Date
Jasper St. Pierre
f506e090ea monitor: Use a more sane dummy configuration for nested mode 2013-08-29 15:26:49 -04:00
Giovanni Campagna
9a4783e364 Integrate the monitor manager with wayland
Use the right backend when running as a wayland compositor,
export the data to wayland clients, and use it to keep the stage
appropriately sized.
2013-08-27 10:09:39 +02:00
Giovanni Campagna
62d908be42 MonitorManager: return the new backlight after changing
Modify the interface of ChangeBacklight to return the new value,
to account for rounding to HW limits.

https://bugzilla.gnome.org/show_bug.cgi?id=706729
2013-08-27 09:58:50 +02:00
Giovanni Campagna
eeb3dfc991 MonitorManager: emit a DBus signal when we change the display configuration
Using out-of-band notifications from the wayland protocol or from
X is racy, in that the client could ask for the new resources before
we have them.
Instead, with a signal, we are sure that when the client asks for
it, it will get the right values.

https://bugzilla.gnome.org/show_bug.cgi?id=706382
2013-08-20 14:08:50 +02:00
Giovanni Campagna
e66db2eab3 MonitorManager: extend the API with physical sizes
These will be needed in the new display panel designs to show
the diagonal length and physical aspect ratio.

https://bugzilla.gnome.org/show_bug.cgi?id=706322
2013-08-20 14:08:50 +02:00
Giovanni Campagna
3bb5086173 Monitor: restore correct display name handling
Now that we have the right values from the EDID, we can load
the PNP database and find the proper vendor name, to show in
the control center UI.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:47:53 +02:00
Giovanni Campagna
57077435ed MonitorManager: add EDID properties to the output DBus description
Add "edid-file", if we have one (in the KMS case, where we can point
people to the right sysfs file), or "edid" with inline data.
These are needed by colord to build the default ICC profile for
uncalibrated displays.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:47:53 +02:00
Giovanni Campagna
46de0ed462 MonitorManager: split the XRandR parts in a subclass
Instead of keeping a forest of if backend else ..., use a subclass
and virtual functions to discriminate between XRandR and the
dummy backend (which lives in the parent class togheter with the
common code)

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:47:53 +02:00
Giovanni Campagna
5086626805 MetaPlugin: add a UI hook for confirming display changes
We want to show a dialog when a display change happens from the
control center. To do so, add a new vfunc to MetaPlugin and
call it when a configuration change is requested via DBus.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:47:53 +02:00
Giovanni Campagna
3b61b85f2c MonitorManager: add gamma support
Add GetCrtcGamma() and SetCrtcGamma(), that wrap the similarly
named XRandR API. These are used by GnomeRR inside the color
plugin of the control center (and may go away if the color
plugin decides to do something different under wayland)

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:47:53 +02:00
Giovanni Campagna
cd20f1bc0b MonitorManager: ignore configuration changes that disable all outputs
If we compute a screen size of 0 in either direction, we crash
later on, as it is invalid for clutter, cogl and X.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:47:53 +02:00
Giovanni Campagna
8b52782ed4 MonitorManager: add support for backlight
GnomeRR needs that too.
The backlight is exported as a normalized 0-100 value, or -1 if not
supported. Clamping to HW limits is handled by the backend.
Changing backlight uses a different method call, to avoid recomputing
the full display configuration every time the user presses the
backlight keys.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:47:53 +02:00
Giovanni Campagna
849050be95 MonitorManager: further extend the dummy backend
The default configuration is extended, which is only possible
if there are as many CRTCs as outputs, so make sure that's true.

Also, add more and bigger modes, so that different sizes will
be chosen for the three outputs.
A nice side effect of this is that with a real 1920x1080 + 1600x900
layout, if you disable the VGA you get a stage that matches the
screen size, which triggers the legacy fullscreen path in the
outside mutter.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:47:52 +02:00
Giovanni Campagna
5c27a91684 MonitorManager: store the presentation mode bit in XRandR
Use a private output property to store if the output is in
presentation mode or not, so that this information is not lost
after the configuration read back from the server.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:34:16 +02:00
Giovanni Campagna
764c472edb MonitorConfig: add support for default configurations
Activate the presentation bit on new hotplugged monitors, while
making a fully extended setup when running for the first time.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:34:16 +02:00
Giovanni Campagna
d0529b7482 MonitorConfig: add CRTC assignment
Ripped off libgnome-desktop, trimming the parts that checked
that the configuration was plausible, as that should be done
in gnome-control-center before asking mutter for a change.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:34:15 +02:00
Giovanni Campagna
8f4621240a MonitorManager: add support for persistent monitor configurations
Add a new object, MetaMonitorConfig, that takes care of converting
between the logical configurations stored in monitors.xml and
the HW resources exposed by MonitorManager.
This commit includes loading and saving of configurations, but
still missing is the actual CRTC assignments and a default
configuration when none is found in the file.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:33:37 +02:00
Giovanni Campagna
e039add240 MonitorManager: add support for DPMS levels
To the XRandR and dummy backend (and as usual the dummy backend
has no effect)

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:33:37 +02:00
Giovanni Campagna
dbd8d4d598 MonitorManager: inherit directly from DisplayConfig instead of handling signals
This way we can handle properties too.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:33:37 +02:00
Giovanni Campagna
522542c486 MonitorManager: fix handling of output transform
Read the current transform from XRandR, and expose the transforms
that are really supported on the bus.
The dummy backend now advertises all transforms, since it doesn't
actually apply them.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:33:35 +02:00
Giovanni Campagna
c354e7e81b DisplayConfig: make the dummy backend writable
Add a number of dummy outputs and modes to the dummy backend,
and implement the writing bits.
The only visible effect is that you can change the screen size,
which resizes the output window.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:32:43 +02:00
Giovanni Campagna
bf40409d97 Reverse handling of XRandR events between Screen and MonitorManager
Now MonitorManager does its own handling of XRandR events, which
means we no longer handle ConfigureNotify on the root window.
MetaScreen reacts to MonitorManager::monitor-changed and updates
its internal state, including the new size.

This paves the way for doing display configuration using only
the dummy backend, which would allow testing wl_output interfaces.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:31:10 +02:00
Giovanni Campagna
57d083730e DisplayConfig: add the write side of the API
Implement ApplyConfiguration in terms of XRandR calls.
Error checking is done before actually committing the configuration.

If mutter is using one of the other monitor config backends, an
error is reported and nothing happens.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:31:09 +02:00
Giovanni Campagna
dc242e46c2 Extend the DBus XRandR protocol to expose cloning restriction
Turns out that even if two outputs say that they can be controlled
by a given CRTC, you can't configure them in the same CRTC unless
they are marked as "possible clones" one of the other.
This can further restrict the configuration options, so we need
to expose this limitation in the DBus API.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:22:54 +02:00
Giovanni Campagna
3bb33d384f Introduce a new DBus interface for display configuration
This new interface will be used by the control center and possibly
the settings daemon to configure the screens. It is designed to
resemble a simplified XRandR, while still exposing all the quirks
of the hardware, so that the panel can limit the user choices
appropriately.

To do so, MetaMonitorMode needs to track CRTCs, outputs and modes,
so the low level objects have been decoupled from the high-level
MetaMonitorInfo, which is used by core and API and offers a simplified
view of HW, that hides away the details of what is cloned and how.
This is still not efficient as it should be, because on every
HW change we drop all data structures and rebuild them from scratch
(which is not expensive because there aren't many of them, but
at least in the XRandR path it involves a few sync X calls)

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:22:54 +02:00
Giovanni Campagna
214f31257b Rework and consolidate monitor handling in MetaScreen
Consolidate all places that deal with output configuration in
MetaScreen, which gets it either from XRandR or from a dummy static configuration.
We still need to read the Xinerama config, even when running xwayland,
because we need the indices for _NET_WM_FULLSCREEN_MONITORS, but
now we do it only when needed.

https://bugzilla.gnome.org/show_bug.cgi?id=705670
2013-08-18 00:22:54 +02:00