1
0
Fork 0
Commit graph

24718 commits

Author SHA1 Message Date
Jonas Ådahl
be13d0f8ee monitor: Allow monitor mode foreach crtc iterator failable
Allow the function used to iterate over the CRTC modes of a monitor
mode to fail, causing the iteration to fail as well.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
81438eebef monitor-unit-tests: Test suggested-x/y configuration
Test the suggested-x/y output state often set by virtual machines.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
b70187c2d9 monitor-manager: Move meta_monitor_manager_ function to right place
Move a meta_monitor_manager_ function to meta-monitor-manager.c where
it belongs.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
c041851fa5 monitor-manager: Rename read_current_config to read_current_state
The function meta_monitor_manager_read_current_config() was renamed to
meta_monitor_manager_read_current_state() as it does not read any
configuration, but reads the current state as described by the backend.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
b59a8b1de3 monitor-manager: Move configuration paths behind 'legacy' functions
In preparation of replacing the configuration system with one working
with high level monitors instead of low level outputs etc, move
configuarion handling code into obviously named function (containing
the word 'legacy'.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
e3b9fe7e58 monitor-manager: Use MetaMonitor to check laptop panel status
Instead of looking at the current configuration, just find the
MetaMonitor of the laptop display panel and check the currest status
directly.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
0177ab45af MetaMonitor: Add _is_laptop_panel() helper
Add a helper to determine whether the monitor is the laptop panel or
not. To be used by the configuration system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
bc951557e8 monitor: Add monitor spec object
A monitor spec object is meant to be used to identify a certain monitor
on a certain output. The spec is unique per actual monitor and connector,
meaning that a monitor that changes from one connector from another
(e.g. HDMI1 to HDMI2) will not be identified as the same. It is meant
to associate for example a configuration entry with an actual monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
2c32d94e1d monitor: Determine preferred monitor mode
Determine the preferred monitor mode given what the preferred CRTC mode
is, and expose it via the API.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
5d9e2d8d2e MetaMonitor: Add mode spec concept
Add a "mode spec" concept, meaning to be used as a identifier for an
actual monitor mode. It consists of details making a mode unique, i.e.
the total resolution and refresh rate. This will later be used to get
the actual monitor mode (set of one or more CRTC modes).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
0637537355 monitor-config: Modernize type declaration
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
63ed134165 monitor-unit-tests: Check monitor modes
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
a6f464a600 monitor: Add monitor modes abstraction
Add "monitor modes" abstracting the modes set on a monitor. On normal
monitors, this directly maps to the CRTC modes, but on tiled monitors,
a monitor mode can consist modes per tiled output.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
0a0c49af71 logical-monitor: Remove outdated comment
Remove the comment about tiling things being calculated. It doesn't add
anything valuable, and tiling is hidden behind MetaMonitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
3c6d688c87 logical-monitor: Don't mirror refresh rate
Let the callers figure out how to associate a logical monitor with a
refresh rate, instead of exposing an arbitrary one.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
5d66a13397 logical-monitor: Don't mirror physical dimensions
Don't try to mirror the physical dimension, since that's a property of
one of the monitors, not of the logical monitor. Callers are changed to
deal with choosing the monitor to represent the logical monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
ff633f295e logical-monitor: Don't duplicate output list
Just use the monitor list and the output lists of each monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
310064601c monitor-unit-tests: Check tiled monitor adding/removing notification
Check that the moniter manager backends get the tiled monitor
added/removed notification.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
78799e58d2 monitor-manager: Make tiled Xrandr monitors based on monitors
Don't deal with adding/removing tiled Xrandr monitors in the generic
backend, but leave it to the Xrandr backend. The tiled monitor will
itself notify the backend when such a monitor is added and removed.

Tiled Xrandr monitors are now based no MetaMonitor instead of
MetaLogicalMonitor. This means that mirrored tiled monitors will now be
represented correctly.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
4fa8b74dc7 monitor-unit-tests: Add musing about test declarations
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
bf8b4e9927 monitor-manager: Generate logical monitors from monitors
Instead of using crtcs and outputs to generate logical monitors, use
the ready made monitor abstraction that hides irrelevant things such as
monitor tiling etc.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
f48acd8448 tests: Check that the crtc gets a logical monitor set
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:54 +08:00
Jonas Ådahl
d0c9d2dc7b tests: Check that the monitors are properly generated
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
d9a0f2a88d monitor-manager: Generate a monitor abstraction from outputs and crtcs
Generate a set of "monitors" abstracting the physical concepts. Each
monitor is built up of one or more outputs; multiple outputs being
tiled monitors. Logical monitors will later be built from these.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
4e812410cc monitor-manager: Move logical monitor into its own file
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
0873e3812b backends: Rename MetaMonitorMode to MetaCrtcMode
The MetaMonitorMode referred to the mode of a CRTC, and with the future
introduction of a MetaMonitor, theh old name would be confusing.
Instead call it what it is.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
7eac28189b monitor-manager: Fix private header guard
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
1650c35e38 monitor-manager: Rename MetaCRTC(Info) to MetaCrtc(Info)
Change to follow the naming convention used everywhere else. This means
changing CRTC to Crtc even though it is an abbreviation.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
156c478ccb tests/monitor: Add HiDPI test
This doesn't test the actual calculation, since that is done in the
backend, it only tests the configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
10e6eae0dd tests/monitor: Add tiled monitor test
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
f519093f89 monitor-manager: Initialize tiled logical monitor scale
The logical monitor scale were not initialized properly when created
for a tiled monitor. Set it to the scale of the main monitor tile.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
8a8ab6c673 tests/monitor: Test preferred mode
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
9e28303588 tests/monitor: Test one out of two outputs being off
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
6776329cf5 tests/monitor: Test two crtcs, one output
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
2e4c516d43 tests/monitor-manager: Add API to emulate a hotplug event
Let a test case pass a test setup, which will be used as the new state
emulated by the test backend.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
d920eaba4a tests: Also make test case verification declarative
Set up the expected result in a declarative way in the same place as
the test case setup is declared. This way we have a completely
declarative way to create test cases.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
376a76a082 tests: Make monitor test case setup more declarative
In order to more easily create more test cases, make the test case
setup more declarative.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
c6d940d3b2 tests: Make monitor unit tests create initial config
This way we have both the test setup and testing in the same file.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
95c101a0ba tests: Use custom Wayland display name
This gets rid of a warning about the Wayland display name already being
taken.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
239671f882 wayland: Add API to override display name
Add API that the tests can use in order to override the Wayland display
name.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
12150c1ca7 tests: Add basic monitor configuration tests
The added test checks that two monitors are lied out on a row next to
each other.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
a251675cc0 tests: Use special purpose backend in unit tests
Use a special purpose backend when running the unit tests. This will
eventually allow testing things like configuration and hot plugging.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
d188949101 backends/x11: Make the X11 backend derivable
Make the X11 backend derivable so that we can base a nested test backend
on it.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:53 +08:00
Jonas Ådahl
d3920ddb67 core: Add private API to override compositor configuration
Add private API for overriding the compositor configuration, i.e. the
compositor type (X11 WM or Wayland compositor) and backend type. This
will make it possible to add a special test backend used by src/tests/.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
bc5077f623 screen: Put xinerama monitor index outside of MetaLogicalMonitor
Put the monitor xinerama index in a separate struct that is attached to
the logical monitor using g_object_set/get_qdata(). Eventually this
should be moved to some "X11 window manager" object, but lets keep it
in MetaScreen until we have such a thing.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
68f3b5849a workspace: Don't keep state given logical monitor indices
Don't store logical monitor specific state in an array where the index
from the monitor manager is used as index locally. Instead just use
table associating a logical monitor with a monitor specific state
holder, and store the state in there. This way we don't have the
workspace implementation relying on implementation details of other
units.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
6de3e4a07e Turn MetaLogicalMonitor into a GObject
This will make it easier to move various manually managed data and data
now in MetaLogicalMonitor into GObject QData fields.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
1fb0e8e9bb monitor-manager: Store logical monitors in a GList
Instead of storing the logical monitors in an array and having users
either look up them in the array given an index or iterate using
indices, put it in a GList, and use GList iterators when iterating and
alternative API where array indices were previously used.

This allows for more liberty regarding the type of the logical monitor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
20b8743f21 monitor-manager: Refactor tiled monitor assembly code
Refactor the tiled monitor assembly code (that constructs a logical
monitor out of tiling information. Part of the reason is to move away
from array based storage, part is to make the code easier to follow,
and part is to separate logical monitor construction from list
manipulation.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00
Jonas Ådahl
016359ede2 window: Remove public meta_window_get_all_monitors API
It's not used anywhere and used monitor indices which is unoptimal.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:52 +08:00