1
0
Fork 0
Commit graph

95 commits

Author SHA1 Message Date
Jonas Ådahl
fb5ebffb8d tests/monitor-unit-tests: Check handling of odd tiled monitors
Add tests for handling tiled monitors where the origin tile output is
not the main output.

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-05-26 14:32:43 +08:00
Jonas Ådahl
94d843b80e tests/monitor-unit-tests: Check meta_monitor_is_active()
https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-05-26 14:32:43 +08:00
Jonas Ådahl
1bb0e18042 monitor-manager/xrandr: Allow configuring scales on X11 too
This commit makes it possible to configure logical monitor scale also
when running on top of an X11 server using Xrandr. An extra property
'requires-globla-scale' is added to the D-Bus API is added to instruct
a configuration application to only allow setting a global logical
monitor scale.

This is needed to let gsd-xsettings use the configured state to set a
XSettings state that respects the explicit monitor configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
2718699ccc backend: Move settings into a new MetaSettings object
Introduce MetaSettings and add the settings managed by MetaBackend into
the new object. These settings include: experimental-features and UI
scaling factor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
c391cefd71 tests: Fix indentation
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
52af529950 tests: Test non-native monitor transform
Test that configuration works as expected when the backend doesn't
support handling the transform and an intermediate offscreen
framebuffer is used.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
c30cb069f5 tests: Make it possible to emulate backend not supporting tranforms
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
99a0b43f28 tests: Derive configuration when stage views is disabled
In order to test deriving the logical state from the underlying
configuration, as is always done on X11, make the test backend derive
the state when stage views are disabled.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
1ad3382bff tests: Test rotation of tiled monitors
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
17c54c6e03 tests: Test that transforms are properly configured
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
dd14e1cebc tests: Add monitor transform config parsing tests
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
afcc1bf512 monitor: Don't keep CRTC position in MetaMonitorCrtcMode
The CRTC position depends on the transform and how the transform is
implemented. The function calculating the positions still doesn't
support anything but the non-transformed case; this commit is in
preparation of adding support for transforms.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
744b4dcb7c tests/monitor-unit-tests: Add tests for custom tiled monitor modes
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
0c64c35a8a monitor-manager: Make the config manager an 'experimental feature'
Instead of using a environment variable, add a new 'experimental
feature' gsetting keyword "monitor-config-manager" that enables the use
of the new MetaMonitorConfigManager. This commit also makes it possible
to switch between the two systems without restarting mutter.

The D-Bus API is disabled when the experimental feature is not enabled,
and clients trying to access it will get a access-denied error in
response. A new property 'IsExperimentalApiEnabled' is added to let the
D-Bus client know whether it is possible to use the experimental API or
not.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
8163ca6821 Add support for scaled logical monitor framebuffers
This commit adds support for rendering onto enlarged per logical
monitor framebuffers, using the scaled clutter stage views, for HiDPI
enabled logical monitors.

This works by scaling the mode of the monitors in a logical monitors by
the scale, no longer relying on scaling the window actors and window
geometry for making windows have the correct size on HiDPI monitors.

It is disabled by default, as in automatically created configurations
will still use the old mode. This is partly because Xwayland clients
will not yet work good enough to make it feasible.

To enable, add the 'scale-monitor-framebuffer' keyword to the
org.gnome.mutter.experimental-features gsettings array.

It is still possible to specify the mode via the new D-Bus API, which
has been adapted.

The adaptations to the D-Bus API means the caller need to be aware of
how to position logical monitors on the stage grid. This depends on the
'layout-mode' property that is used (see the DisplayConfig D-Bus
documentation).

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
f25f14351c monitor-manager: Make max screen size optional
Make the concept of maximum screen size optional, as it is not
necessarily a thing on all systems (e.g. when using the native backend
and stage views).

The meta_monitor_monitor_get_limits() function is replaced by a
meta_monitor_manager_get_max_screen_size() which fails when no screen
limit is available. Callers and other users of the previous max screen
size fields are updated to deal with the fact that the limit is
optional.

The new D-Bus API is changed to move it to the properties bag, where
its absence means there is no applicable limit.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
691e7951ea DisplayConfig: Add new API for configuring monitors
Add a new D-Bus API that uses the state from GetCurrentState to
configure high level monitors, instead of low level CRTCs and
connectors. So far persistent configuration is not implemented, as
writing to the configuration store is still not supported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:48 +08:00
Jonas Ådahl
0548c9e7d5 MetaMonitorConfig: Rename is_underscanning to enable_underscanning
Use better terminology to imply that the configuration enables
underscanning, not what already "is".

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
2035f2f2e2 monitor-config-manager: Verify that logical monitors are adjecent
Logical monitors in a configuration must be adjecent to each other,
meaning there will be at least one pixel long side touching some other
logical monitor.

The exception to this is when there is only one logical monitor, which
cannot be adjecent to any other.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
d050fdb17f monitor-manager: Add per backend capabilities
Add a private API for querying backend capabilities. For now, only
mirroring capability is reported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
9e8ee491e6 monitor-manager: Add API to get scales supported by the backend
For the Xrandr backend, only scale 1 is supported, for the others, 1
and 2 are reported as supported.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
fcc0288f0c monitor-manager: Let the backends handle no configuration
Let the backends decide whether to just rebuild a derived state, or use
the NULL config to rebuild an empty logical state.

This also changes the expected screen size values of the no-outputs
test; as this case is actually handled now.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
4e03e89869 tests: Check that mirroring is configured properly
This test checks that mirroring works when using separate CRTCs. It
does not check cloning.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
4e17017501 monitor-unit-tests: Check custom tiled monitor config
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
63bc86cd43 tests: Test configured custom logical monitor scale
Check that a configured logical monitor scale overrides any calculated
one.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:47 +08:00
Jonas Ådahl
a393a614a1 monitor-manager: Remove 'scale' from MetaOutput
Replace the 'scale' of an output with a vfunc on the MetaMonitorManager
class that takes a monitor and a monitor mode which calculates the
scale. On X11 this always returns 1, on KMS, the old formula is used.
On the dummy and test backends, the already configured values are
returned.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:46 +08:00
Jonas Ådahl
944339f6a5 monitor-manager: Expose whether the backend handles a transform
Expose via a new API whether the transform on a logical monitor is
handled by the backend. This was previously only exposed only in the
native backend. This will be used to emulate not supporting transforms
in the backend in the nested backend.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
e20e60783a tests: Make test backend inherit MetaBackendX11Nested
The test backend must inherit the nested backend, as MetaBackendX11 is
not complete.

https://bugzilla.gnome.org/show_bug.cgi?id=779745
2017-03-09 10:17:30 +08:00
Jonas Ådahl
6fa8238ebf monitor-unit-tests: Check monitor <-> logical monitor relationships
Make sure that each logical monitor owns the expected actual monitors.
This currently needs special care when dealing with laptop lid the
configuration, as the MetaMonitorConfigManager path still deosn't
handle restoring the previous configuration, meaning the logical
monitor with the external monitor will continue being primary.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:57 +08:00
Jonas Ådahl
1c6eef48f1 monitor-unit-tests: Move logical monitor checking into separate function
Split the big check function, makes things easier to read.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:57 +08:00
Jonas Ådahl
1fdf2ac746 monitor-unit-tests: Check that each CRTC mode is correct
This is partly redundant given that the current monitor mode is checked
against the CRTC mode, but this also checks the disabled CRTCs. Later
the configured mode position and transform will be checked.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
3ae9feef0c monitor-unit-tests: Check monitor mode CRTC mode positions
Check that the crtc mode has the correct intra-monitor position. In
effect, this tests that the CRTCs in a tiled monitor are configured with
the correct mode on the correct position.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
e9a8208607 tests: Add monitor store and config test for output underscanning
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
0fd9c00580 tests: Add monitor and monitor store test for custom primary
Test that having a custom primary logical monitor is configured as
expected.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
4a51a1dfe5 monitor-unit-tests: Check handling of the primary presentation flags
The main output of the main (first) monitor of a primary logical
monitor should have the MetaOutput::is_primary field set; all other
outputs should have it not set.

All outputs associated with a logical monitor with presentation set
should have MetaOutput::is_presentation set. No other outputs should
have it set.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
9fb8abf840 monitor-store-unit-tests: Check the primary and presentation flags
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
449320cd23 monitor-unit-tests: Check that a stored config is preferred
Check that the stored config (where the logical monitors are placed
vertically) is preferred to the otherwise generated linear config.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
12b69dbabb monitor-unit-tests: Make hotplug_mode_update optional
Add a flag to the test setup creation function enabling the caller to
specify whether a stored config should be used. This is done by
changing the value of the hotplug_mode_update MetaOutput field,
normally used by VMs to do the same.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
4652bde3d7 tests: Move monitor test helpers to a helper file
Both the monitor unit tests and monitor store unit tests will want to
check whether the config manager is used and set custom configuration
files.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
702facbc91 monitor-store-unit-tests: Add test for vertical placement
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
339340df34 tests: Add MetaMonitorConfigStore tests
Add tests that check that a XML configuration file results in correct
MetaMonitorsConfig objects.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
28a8c714ea unit-tests: Pass argc/argv directly to g_test_init
Don't let a dummy option context consume the arguments; just let the
GLib test suite do it. It'll handle the basic command line arguments
and allow doing things such as specifying what test to run.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
c9f18bfef3 monitor-unit-tests: Test headless mode
This tests only the monitor configuration and basic functionality. It
does not test anything related to window management and Wayland client
interaction.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
f45e7703ba monitor-unit-tests: Add lid-closed with no external monitor test case
Test that when the laptop lid is closed, but no external monitors are
connected, that we still have a mode set on the laptop panel.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
1ee0412177 monitor-unit-tests: Use g_assert_cmp* macros when suitable
Use the g_assert_cmp(int|uint|...) macros when comparing integers and
unsigned integers. This means that the mismatched numbers are printed
in the test report.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:56 +08:00
Jonas Ådahl
81923410f6 monitor-unit-tests: Test starting with lid closed
Add a test case that checks that configuration works when the lid is
initialy closed then later opened. This test case is disabled when the
legacy configuration is used as it does not handle that situation.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
cde1a730e8 monitor-unit-tests: Add laptop lid switch test case
Test that the laptop panel is disabled if the lid is closed.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
d6efdfab4b monitor-unit-tests: Mock laptop lid state
For now, always assume the laptop lid is open, as all test cases assume
this.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
8d1be7ffc0 monitor-unit-tests: Add test for handling too few CRTCs
Check that configuration when there are more outputs than CRTCs does
something sane.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00
Jonas Ådahl
644ee666f6 Introduce new monitor configuration system
The new monitor configuration system (MetaMonitorConfigManager) aims to
replace the current MetaMonitorConfig. The main difference between the
two is that MetaMonitorConfigManager works with higher level input
(MetaMonitor, MetaMonitorMode) instead of directly looking at the CRTC
and connector state. It still produces CRTC and connector configuration
later applied by the respective backends.

Other difference the new system aims to introduce is that the
configuration system doesn't manipulate the monitor manager state; that
responsibility is left for the monitor manager to handle (it only
manages configuration and creates CRTC/connector assignments, it
doesn't apply anything).

The new configuration system allows backends to not rely on deriving the
current configuration from the CRTC/connector state, as this may no longer be
possible (i.e. when using KMS and multiple framebuffers).

The MetaMonitorConfigManager system is so far disabled by default, as
it does not yet have all the features of the old system, but eventually
it will replace MetaMonitorConfig which will at that point be removed.
This will make it possible to remove old hacks introduced due to
limitations in the old system.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-01-25 16:28:55 +08:00