1
0
Fork 0
Commit graph

250 commits

Author SHA1 Message Date
Jonas Ådahl
f71316c850 output: Move configureable state to instance private
That is is_presentation, is_primary, is_underscanning and backlight.

The first three are set during CRTC assignment as they are only valid
when active. The other is set separately, as it is untied to
monitor configuration.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1287
2020-06-10 18:54:50 +00:00
Jonas Ådahl
e063947a16 output: Move winsys_id into instance private and rename to id
https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1287
2020-06-10 18:54:50 +00:00
Jonas Ådahl
a42eed0231 crtc: Move CRTC id field into instance private
Set during construction, retrieved using helper.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1287
2020-06-10 18:54:50 +00:00
Jonas Ådahl
0a6034ef3a monitor-manager: Remove 'mirror' capability
With per-CRTC views, there is nothing stopping NVIDA EGLStream based
rendering to not support monitor mirroring, so lets remove that
restriction.

https://gitlab.gnome.org/GNOME/mutter/-/merge_requests/1098
2020-03-18 00:46:20 +00:00
Jonas Ådahl
fe42d56db3 crtc: Move configured state to separate struct
To make it more reliable to distinguish between values that are read
from the backend implementation (which is likely to be irrelevant for
anything but the backend implementation), split out those values (e.g.
layout).

This changes the meaning of what was MetaCrtc::rect, to a
MetaCrtcConfig::layout which is the layout the CRTC has in the global
coordinate space.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/1042
2020-02-25 18:39:51 +01:00
Robert Mader
8e172aeecb cleanup: Use g_clear_handle_id() for g_source_remove()
It makes sure we do not forget to zero the id and lets us avoid
zero checks before. We use it for all new code, lets clean up the
existing code base.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/947
2019-11-22 01:27:40 +01:00
Robert Mader
92375c75f8 cleanup: Use g_clear_signal_handler() where possible
This is inspired by 98892391d7 where the usage of
`g_signal_handler_disconnect()` without resetting the corresponding
handler id later resulted in a bug. Using `g_clear_signal_handler()`
makes sure we avoid similar bugs and is almost always the better
alternative. We use it for new code, let's clean up the old code to
also use it.

A further benefit is that it can get called even if the passed id is
0, allowing us to remove a lot of now unnessecary checks, and the fact
that `g_clear_signal_handler()` checks for the right type size, forcing us
to clean up all places where we used `guint` instead of `gulong`.

No functional changes intended here and all changes should be trivial,
thus bundled in one big commit.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/940
2019-11-21 15:02:27 +00:00
Cosimo Cecchi
8665084df1 monitor-manager: check for underscan setting validity upfront
Instead of doing a roundtrip to the X server before setting it, rely on
the previous value fetched before the configuration was sent over DBus.
This matches the argument check we already do elsewhere, and will allow
us to more easily add an additional condition to determine if underscan
is supported.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/673
2019-10-16 14:34:14 +00:00
Carlos Garnacho
97010ac64d meta: Move private defines to a private header
These defines are unused outside of mutter, and actually not
desirable to export. Move them to a private header.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/859
2019-10-15 11:03:56 +00:00
Robert Mader
a8155a0471 meta: Add META namespace to macros
To silence warnings during GIR generation.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/822
2019-10-14 10:14:11 +00:00
Georges Basile Stavracas Neto
4a184d74d5
monitor-manager: Don't notify unchanged power save mode
Since 4cae9b5b11, and indirectly before that as well, the
MetaMonitorManager::power-save-mode-changed is emitted even
when the power save mode didn't actually change.

On Wayland, this causes a mode set and therefore a stuttering.
It became more proeminent with the transactional KMS code.

Only emit 'power-save-mode-changed' when the power save mode
actually changed.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/674
2019-07-06 20:23:57 -03:00
Olivier Fourdan
bca08c2c4e monitor-manager: Use meta_monitor_get_display_name() API
Use the new monitor's `meta_monitor_get_display_name()` instead of
rebuilding the display name for each DBUS request.

https://gitlab.gnome.org/GNOME/mutter/issues/645
2019-06-28 11:19:22 +02:00
Olivier Fourdan
6541d49fe7 monitor: Add display name
The display name is being used by the monitor manager to expose to name
to the DBUS API.

It is being rebuilt each time, so instead build the displa yname once
for the monitor and keep it around, with an API to retrieve it, so that
we can reuse it in preparation of xdg-output v2 support.

https://gitlab.gnome.org/GNOME/mutter/issues/645
2019-06-28 11:19:22 +02:00
Olivier Fourdan
c3c6668343 monitor-manager: Add get_vendor_name API
The monitor manager keeps the list of PnP Ids, add a new API to get the
vendor name from a given PnP ID.

https://gitlab.gnome.org/GNOME/mutter/issues/645
2019-06-28 11:19:22 +02:00
Jonas Ådahl
5c500ad402 backend: Move GPU ownership from the monitor manager to the backend
Lets work towards making MetaMonitorManager about managing monitors, and
not about managing GPUs. This changes other units to keep a pointer to
the backend instead of a monitor manager, in case their ownership
changed, or their main usage of the monitor manager was to look up GPUs.

https://gitlab.gnome.org/GNOME/mutter/issues/548
https://gitlab.gnome.org/GNOME/mutter/merge_requests/525
2019-06-20 13:31:55 +00:00
Jonas Ådahl
4cae9b5b11 monitor-manager: Clean up DPMS state tracking
DPMS is configured from a bit all over the place: via D-Bus, via X11 and
when reading the current KMS state. Each of these places did it slightly
differently, directly poking at the field in MetaMonitorManager.

To make things a bit more managable, move the field into a new
MetaMonitorManagerPrivate, and add helpers to get and set the current
value. Prior to this, there were for example situations where the DPMS
setting was changed, but without signal listeners being notified about
it.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/506
2019-04-02 13:49:59 +00:00
Marco Trevisan (Treviño)
9b8510ac56 monitor: Fix indentation style on calculate_supported_scales and friends
https://gitlab.gnome.org/GNOME/mutter/merge_requests/488
2019-03-12 00:15:42 +00:00
Niels De Graef
1c6ea5d1db Use a consistent style for enum braces
https://gitlab.gnome.org/GNOME/mutter/merge_requests/361
2019-02-28 09:31:01 +01:00
Jonas Ådahl
20c5e2525e monitor-manager: Provide proper contexts for translators
Two strings were both "%s %s", but with different meaning. Let
translators know the difference by providing context using C_().
2019-02-04 18:41:05 +01:00
Dariusz Gadomski
325fec31da monitor-manager: Add yet another wacky "physical dimension" 2019-02-04 17:41:36 +01:00
Dariusz Gadomski
cbb2a286f2 monitor-manager: Don't use wacky physical dimensions in display name 2019-02-04 17:41:36 +01:00
Dariusz Gadomski
e9eaa37401 monitor-manager: Use output name as display name in GetResources 2019-02-04 17:41:36 +01:00
Florian Müllner
d5a7bbd094 Fix builds with G_DISABLE_ASSERT
Commit 25f416c13d added additional compilation warnings, including
-Werror=return-type. There are several places where this results
in build failures if `g_assert_not_reached()` is disabled at compile
time and the compiler misses a return value.

https://gitlab.gnome.org/GNOME/mutter/issues/447
2019-01-25 09:43:06 +01:00
Marco Trevisan (Treviño)
e352011830 MonitorManager: Use composition instead of inheriting from dbus skeleton
MonitorManager was inheriting from MetaDBusDisplayConfigSkeleton, this was
causing introspection to see this like a GDBus skeleton object exposing to
clients methods that were not required.

Also, this required us to export meta_dbus_* symbols to the library, while
these should be actually private.

So, make MetaMonitorManager to be just a simple GObject holding a skeleton
instance, and connect to its signals reusing most of the code with just few
minor changes.

https://gitlab.gnome.org/GNOME/mutter/merge_requests/395
2019-01-23 14:12:07 +01:00
Jonas Ådahl
b448ced8e4 backends: Silence a couple of gtk-doc warnings
A lot of fancy gtk-doc documentation was added, but they had a couple of
issues: invalid return value annotations and wrong documented function
name.
2019-01-08 09:06:11 +01:00
Niels De Graef
0478c225b7 Add some gtk-doc comments. 2019-01-06 21:57:16 +01:00
Jonas Ådahl
149e4d6934 monitor-manager: Don't use switch-config when ensuring configuration
Switch-configs are only to be used in certain circumstances (see
meta_monitor_manager_can_switch_config()) so when ensuring
configuration and attempting to create a linear configuration, use the
linear configuration constructor function directly without going via the
switch config method, otherwise we might incorrectly fall back to the
fallback configuration (only enable primary monitor).

This is a regression introduced by 6267732bec.

Fixes: https://gitlab.gnome.org/GNOME/mutter/issues/342
2018-12-13 12:40:27 +00:00
Niels De Graef
49cb691bb5 monitor-manager: remove get_edid_file() vfunc
It wasn't implemented by any subclass, it's not provided by DRM either.
And even if a subclass were to have only a file available, it could read
it into a GBytes as well and just use `read_edid()`.

Found this while working on !269.
2018-11-26 14:37:54 +01:00
Jonas Ådahl
2f4a68c8c3 Clean up include macros mess
The order and way include macros were structured was chaotic, with no
real common thread between files. Try to tidy up the mess with some
common scheme, to make things look less messy.
2018-11-06 17:17:36 +01:00
Daniel Drake
6267732bec monitor-manager: use MonitorsConfig to track switch_config
When constructing MetaMonitorsConfig objects, store which type
of switch_config they are for (or UNKNOWN if it is not such
type of config).

Stop unconditionally setting current_switch_config to UNKNOWN when
handling monitors changed events. Instead, set it to the switch_config
type stored in the MonitorsConfig in the codepath that updates logical
state. In addition to being called in the hotplug case along the same
code flow that generates monitors changed events, this is also called
in the coldplug case where a secondary monitor was connected before
mutter was started.

When creating the default linear display config, create it as a
switch_config so that internal state gets updated to represent
linear mode when this config is used.

The previous behaviour of unconditionally resetting current_switch_config
to UNKNOWN was breaking the internal state machine for display config
switching, causing misbehaviour in gnome-shell's switchMonitor UI when
using display switch hotkeys. The lack of internal tracking when the
displays are already in the default "Join Displays" linear mode was
then causing the first display switch hotkey press to do nothing
(it would attempt to select "Join Displays" mode, but that was already
active).

Fixes: https://gitlab.gnome.org/GNOME/mutter/issues/281
https://gitlab.gnome.org/GNOME/mutter/merge_requests/213
2018-10-08 15:53:45 +08:00
Andrea Azzarone
649c26e05a monitor-manager: Filter out low screen resolutions
Avoid exporting through org.gnome.Mutter.DisplayConfig.GetCurrentState
excessively-low screen resolutions setting both a minimum width and a minimum
height. GetCurrentState is e.g. used by Gnome Control Center to build a list of
selectable resolutions.

Fixes: https://bugzilla.gnome.org/show_bug.cgi?id=793223
2018-07-30 15:57:31 +02:00
Bastien Nocera
951219650f backend: Move lid-is-closed handling to MetaBackend
Rather than handle UpClient in both MetaBackend (to reset the idletime
when the lid is opened), and in MetaMonitorManager and
MetaMonitorConfigManager (to turn the screen under the lid on/off
depending on its status), move the ability to get the lid status from
UPower or mock it in one place, in MetaBackend.
2018-07-18 10:17:36 +00:00
Bastien Nocera
49b23c7490 monitor-manager: Cache the last known value of "lid-is-closed"
Restarting UPower will make every property of UpClient emit a "notify"
signal (as a GDBusProxy would). Avoid mutter reconfiguring the displays
when upower restarts by caching the last known value of "lid-is-closed"
and only reconfiguring the displays if it actually changed.

This fixes a black out of the screen when UPower restarts.
2018-07-18 10:17:35 +00:00
Bastien Nocera
644a618fb1 monitor-manager: Don't throw an error if UPower isn't running
Don't try to connect to a UpClient signal if creating the client failed,
because UPower isn't running for example.
2018-07-18 10:17:34 +00:00
Armin Krezović
390314adfb Rename errors.[ch] to meta-x11-errors.[ch]
Also rename meta_error_trap_* to meta_x11_error_trap_* and
move meta-x11-errors.c to src/x11

https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:17 +02:00
Armin Krezović
e1c67a1824 Move monitor management API to MetaDisplay
This includes changing various users to use MetaDisplay directly, who
used MetaScreen only for this before.

https://bugzilla.gnome.org/show_bug.cgi?id=759538
2018-07-06 19:47:16 +02:00
Jonas Ådahl
1200182d70 backends: Move MetaOutput::crtc field into private struct
No functional changes. This is only done so that changes to reference
counting can done more reliably.

https://bugzilla.gnome.org/show_bug.cgi?id=786929
2018-06-28 13:42:15 +02:00
Jonas Ådahl
d9c18fd5bb monitor-manager: Add back warning messages
For some reason "backends: Remove X11 idle-monitor backend" removed
unrelated warning messages for when generated monitor configurations
that should work didn't, which also made the unit tests fail.

This commit adds them back, which also makes the tests pass again.
2018-06-28 11:23:39 +00:00
Jonas Ådahl
0b3a1c9c31 monitor-manager: Find active monitor when deriving global scale
When deriving the global scale directly from the current hardware state
(as done when using the X11 backend) we are inspecting the logical
state they had prior to the most recent hot plug. That means that a
primary monitor might have been disabled, and a new primary monitor may
not have been assigned yet.

Stop assuming a primary monitor has an active mode before having
reconstructed the logical state by finding some active monitor if the
old primary monitor was disabled. This avoids a crash when trying to
derive the global scale from a disabled monitor.

Closes: https://gitlab.gnome.org/GNOME/mutter/issues/130
2018-04-25 10:50:50 +02:00
Bastien Nocera
7945ee5beb backends: Remove X11 idle-monitor backend
And use the old "native" backend for both X11 and Wayland. This will
allow us to share fixes between implementations without having to delve
into the XSync X11 extension code.

https://bugzilla.gnome.org/show_bug.cgi?id=705942
2018-04-16 13:28:03 +02:00
Aleksandr Mezin
5ad34e0efb monitor-manager: fix output ids returned by GetResources
Output ID is set equal to 'i' later in the loop. But 'i' was never
incremented, so all outputs were getting the same ID (equal to
the number of CRTCs, because 'i' was reused from the previous loop).


(cherry picked from commit 23c3f8bb18db499d196f1024732ef3234b44f59c)
2018-04-11 17:57:25 +00:00
Hans de Goede
e59ca14f6c monitor-manager: Take panel orientation into account when getting input matrix
If a LCD panel has a non normal orientation (mounted upside-down or 90
degrees rotated) then the kernel will report touchscreen coordinates with
the origin matching the native (e.g. upside down) coordinates of the panel.

Since we transparently rotate the image on the panel to correct for the
non normal panel-orientation, we must apply the same transform to input
coordinates to keep the aligned.

https://bugzilla.gnome.org/show_bug.cgi?id=782294
2017-12-25 17:01:45 +08:00
Jonas Ådahl
b7518c8651 monitor-manager: Compare keys when checking whether a config is complete
We only counted configured monitors and whether the config was
applicable (could be assigned), howeverwe didn't include disabled
monitors when comparing. This could caused incorrect configurations to
be applied when trying to use the previous configuration.

One scenario where this happened was one a system with one laptop
screen and one external monitor that was hot plugged some point after
start up. When the laptop lid was closed, the 'previous configuration'
being the configuration where only the laptop panel was enabled, passed
'is-complete' check as the number of configured monitors were correct,
and the configuration was applicable.

Avoid this issue by simply comparing the configuration key of the
previous configuration and the configuration key of the current state.
This correctly identifies a laptop panel with the lid closed as
inaccessible, thus doesn't incorrectly revert to the previous
configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=788915
2017-11-30 11:48:44 +08:00
Rui Matos
28a9439209 monitor-manager: Refuse to activate closed laptop panels
There's no good reason to allow this and it allows g-c-c to properly
show that such a configuration doesn't work.

https://bugzilla.gnome.org/show_bug.cgi?id=790336
2017-11-22 15:07:11 +01:00
Carlos Garnacho
89f5ca3301 backends: Unref variants obtained from g_variant_iter_get_next_value()
Those are being leaked.

https://bugzilla.gnome.org/show_bug.cgi?id=789553
2017-10-27 13:22:12 +02:00
Marco Trevisan (Treviño)
f044511037 monitor-manager: use g_return_val_if_fail if trying to fetch an invalid monitor
https://bugzilla.gnome.org/show_bug.cgi?id=788860
2017-10-13 13:43:03 +08:00
Marco Trevisan (Treviño)
b31e545c9d backends: add 'monitors-updated-internal' signal to only update internal state
Adding an internal signal and use it to update the internal state before
emitting "monitors-changed" which will be repeated by the screen to the world.

https://bugzilla.gnome.org/show_bug.cgi?id=788860
2017-10-13 00:42:50 -05:00
Jonas Ådahl
fad5657eda DisplayConfig: Add 'legacy-ui-scaling-factor' property
We have this value in mutter; lets share it so that for example
gnome-settings-daemon doesn't have to calculate it itself.

https://bugzilla.gnome.org/show_bug.cgi?id=788820
2017-10-12 17:42:52 +08:00
Jonas Ådahl
c1683073f1 backends: Split out CRTC/output management to MetaGpu
In order to eventually support multilpe GPUs with their own connectors,
split out related meta data management (i.e. outputs, CRTCs and CRTC
modes) into a new MetaGpu GObject.

The Xrandr backend always assumes there is always only a single "GPU" as
the GPU is abstracted by the X server; only the native backend (aside
from the test backend) will eventually see more than one GPU.

The Xrandr backend still moves some management to MetaGpuXrandr, in
order to behave more similarly to the KMS counterparts.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 18:05:20 -04:00
Jonas Ådahl
18ec86bd90 Remove meta_monitor_manager_get_monitor_for_output() API
This function is replaced by an equivalent that takes a connector
string.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
315a6f43d7 monitor-manager: Keep pointer to backend
Instead of accessing the global singleton, keep a pointer to the
backend in the MetaMonitorManager struct.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
518fb9fb5e backends: Split monitor manager creation into create and setup
The monitor manager instance was created and setup in one step; at
construction. This is problematic if, in the future, the monitor manager
creation can fail, as the monitor manager is created quite late.

To make it possible to in the future fail creating a monitor manager,
create the instance very early when initiating the backend, then on
post init backend setup, "setup" the monitor manager state, i.e. read
the current state and setup the stage.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
2db5505216 monitor-manager: Turn MetaCrtcMode into a GObject
Convert MetaCrtcMode from a plain struct to a GObject. This changes the
storage format, and also the API, as the API was dependent on the
storage format.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
f64fab1d2d monitor-manager: Make MetaCrtc a GObject
Turn MetaCrtc into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaCrtcs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
a62e9f99a2 backends: Remave unused meta_monitor_manager_get_resources() API 2017-10-05 16:18:43 -04:00
Jonas Ådahl
9817a6aa47 Make MetaOutput a GObject
Turn MetaOutput into a GObject and move it to a separate file. This
changes the storage format, resulting in changing the API for accessing
MetaOutputs from using an array, to using a GList.

https://bugzilla.gnome.org/show_bug.cgi?id=785381
2017-10-05 16:18:43 -04:00
Jonas Ådahl
ea4dbd14bc monitor-config: Keep track of disabled monitors for stored configs
When saving and restoring monitor configurations, we must take disabled
monitors into account, as otherwise one cannot store/restore a
configuration where one or more monitors are explicitly disabled. Make
this possible by adding a <disabled> element to the <configure> element
which lists the monitors that are explicitly disabled. These ones are
included when generating the configuration key, meaning they'll be
picked up correctly.

https://bugzilla.gnome.org/show_bug.cgi?id=787629
2017-10-02 15:34:24 -04:00
Jonas Ådahl
22cdc8f414 monitor-manager: Pass config to derive from when updating state
When we update state, we might not have set the current config yet (for
example if the Xrandr assignment didn't change), so pass the monitors
config we should derive from instead of fetching it from the monitor
config manager.

https://bugzilla.gnome.org/show_bug.cgi?id=787477
2017-09-20 17:26:32 +08:00
Jonas Ådahl
a119e58773 backend: Only try to center pointer when there not headless
Don't attempt to center the pointer when there is nothing to center on.

https://bugzilla.gnome.org/show_bug.cgi?id=730551
2017-08-30 13:09:38 +08:00
Jonas Ådahl
3005a400ca monitor-manager: Add helper for getting monitor from connector
This will be used later.

https://bugzilla.gnome.org/show_bug.cgi?id=784199
2017-08-29 11:49:01 +08:00
Jonas Ådahl
6584d06bb5 monitor-manager: Don't cancel confirm dialog on verifying
When another D-Bus call that just tries to verify a configuration is
made, don't cancel any active monitor configuration dialog, as doing so
would effectively confirm queried configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=786023
2017-08-21 21:20:19 +08:00
Jonas Ådahl
35c9280fb6 monitor-manager: Try to restore previous config before regenerating
When opening a laptop lid, one will likely want to restore the
configuration one had prior to closing it, so when ensuring monitor
configuration, first try to see if the previously set configuration is
both complete (all connected monitors are configured) and applicable
(it is a valid configuration) and only try to generate a new from
scratch if that failed.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
b140e7fbeb monitor-config-manager: Keep short history of configurations
In order to go back in monitor configurations, save them to a history.
The history is implemented as a max 3 element long queue, where newly
set configurations are pushed to the head, and old are popped from the
tail.

The difference between using a single previous config reference and a
queue is that we can now remember the configuration used prior to a
D-Bus triggered configuration when the user discarded the configuration.

This will later be used to restore a previous configuration when a
laptop lid is opened.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
bc3162460f Migrate old monitor configuration files to new system
This commit changes the new configuration system to use monitors.xml
instead of monitors-experimental.xml. When starting up and the
monitors.xml file is loaded, if a legacy monitors.xml file is
discovered (it has the version number 1), an attempt is made to migrate
the stored configuration onto the new system.

This is done in two steps:

1) Parsing and translation of the old configuration. This works by
parsing file using the mostly the old parser, but then translating the
resulting configuration structs into the new configuration system. As
the legacy configuration system doesn't carry over some state (such as
tiling and scale used), some things are not available. For tiling, the
migration paths makes an attempt to discover tiled monitors by
comparing EDID data, and guessing what the main tile is. Determination
of the scale of a migrated configuration is postponed until the
configuration is actually applied. This works by flagging the
configuration as 'migrated'.

2) Finishing the migration when applying. When a configuration with the
'migrated' flag is retrieved from the configuration store, the final
step of the migration is taken place. This involves calculating the
preferred scale given the mode configured, while making sure this
doesn't result in any overlapping logical monitor regions etc.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
88f2441330 monitor-manager: Fix output variable naming
Fix the last case of using the variable name "meta_output" for a
MetaOutput.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:23:51 +08:00
Jonas Ådahl
e8a62861c9 Remove old monitor configuration system
Remove the old MetaMonitorConfig system and mark the new one as
non-experimental. This also removes the D-Bus property.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-08-21 12:20:53 +08:00
Cosimo Cecchi
1455c402b9 monitor-manager: add API to get the display configuration timeout
Instead of hardcoding this into two different places, add an API so that
gnome-shell can fetch it.

https://bugzilla.gnome.org/show_bug.cgi?id=767805
2017-07-31 15:41:15 +01:00
Rui Matos
3f9c5823cb backends: Add API to switch to predetermined monitor configurations
This will allows us to support the XF86Display key present on some
laptops, directly in mutter. This is also known, in evdev, as
KEY_SWITCHVIDEOMODE.

The common usage for this key is to alternate between a few well known
multi-monitor configurations though these aren't officially
standardized. As an example, Lenovo documents it as:

"Switches the display output location between the computer display
and an external monitor."

On this patch, we're just introducing the configurations that have been
implemented in g-s-d until now, which go a bit beyond the above
description.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-19 11:18:53 +02:00
Jonas Ådahl
32fd1e8c08 monitor-manager: Let the MetaMonitor derive the whole layout
Instead of letting MetaMonitor derive the logical monitor size, then
using the main monitor for the position, just let MetaMonitor derive
the whole layout including the position. This means it can deal with
tiled monitors better, for example when the main output (the output
always active when the monitor is active) is not the origin output (the
output with tile position (0, 0)).

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-07-19 17:06:17 +08:00
Florian Müllner
8b5d34b24a monitor-manager: Shut up a compiler warning
Add a default switch statement to make it clear that 'transform'
won't be used uninitialized.
2017-07-14 16:56:43 +02:00
Rui Matos
7360f51ee8 meta-monitor-manager: Add API to rotate the current configuration
This will allows us to support the XF86RotateWindows key present on
some laptops directly in mutter.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-14 15:31:20 +02:00
Rui Matos
6ae42f3845 monitor-manager: Hook MetaOrientationManager to change the config
On orientation changes we'll apply the appropriate monitor transform
to the current configuration if possible.

https://bugzilla.gnome.org/show_bug.cgi?id=781906
2017-07-14 15:31:20 +02:00
Jonas Ådahl
777963eeb6 monitor-manager: Don't set current config if only verifying
When verifying if a configuration is applicable, don't set it as
current when applying succeeded, or else reverting to a previous
configuration doesn't work after having verified.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
49c5228655 DisplayConfig: Add support for interlaced modes
Differentiate between non-interlaced and interlaced modes. This is done
by appending an "i" after the resolution part of the mode ID, and
adding a 'is-interlaced' (b) property to the mode properties.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
0a8e108f10 DisplayConfig: Replace mode 'u' flags with 'a{sv}' property bag
To be more flexible without having to change any D-Bus type signatures
in the future, replace the 'uint' flags value (currently determining
whether a mode is current and/or preferred) with a variant lookup table.

The keys 'is-current' (b) and 'is-preferred' (b) replace the existing
flags.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
859b01fc39 DisplayConfig: Specify mode ID string instead of mode spec
To be able to add more modes types that happen to have the same
resolution and refresh rate, change the API to specify modes using an
ID string. The ID string is temporary, and only works for associating a
mode for the monitor instance that it was part of.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
41eea5a942 monitor-config: Handle fractional scale precision loss
When calculating sizes given some size and a fractional logical monitor
scale with precision loss, round the result of the floating point
calculation to the closest integer, as otherwise we might end up with
result smaller by 1 if there was a loss of precision when calculating
the scale.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:27 +08:00
Jonas Ådahl
67eb289a6a monitor-manager: Find the supported scales from one passed
When passing scales over D-Bus, we'll loose some precision. To set the
correct scale, use the configured scale and look up the one actually
supported by the monitor mode, and use that. To match the supported one
with the configured one, the difference must be within rounding error
range.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
b2a530b326 DisplayConfig: Make supported scales per mode
This changes the API to pass supported scales per mode instead of
providing a global list. This allows for more flexible scaling
scenarious, where a scale compatible with one mode can still be made
available even though another mode is incompatible.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
10b0351a59 Add support for rudimentary fractional scaling
When the logical layout mode is used, allow configuring the scaling to
be non-integer. Supported scales are so far hard coded to include at
most 1, 1.5 and 2, and scales that doesn't result in non-fractional
logical monitor sizes are discarded.

Wayland outputs are set to have scale ceil(actual_scale) meaning well
behaving Wayland clients will provide buffers with buffer scale 2, thus
being scaled down to the fractional scale.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Jonas Ådahl
b64c69e4bc logical-monitor: Make scale a float
To support fractional scaling, the logical monitor scale must be stored
as a float. No other functional changes is part of this commit.

https://bugzilla.gnome.org/show_bug.cgi?id=765011
2017-07-14 20:54:26 +08:00
Bastien Nocera
f5f0ff0a2f monitor-manager: Fix crash when UPower is not available
Don't access the upower client if it doesn't exist

https://bugzilla.gnome.org/show_bug.cgi?id=780407
2017-05-31 16:11:24 +02:00
Jonas Ådahl
82325cbcfd monitor: Don't get the monitor manager from the backend
We will both create and destroy monitors during initialization (when
using the X11 backend), so don't try to access the monitor manager from
the backend, but store a pointer to it instead.

It's stored in MetaMonitor even though only MetaMonitorTiled uses it,
mostly because it makes more sense to store such a pointer there.

https://bugzilla.gnome.org/show_bug.cgi?id=781723
2017-05-26 14:32:43 +08:00
Jonas Ådahl
1bb0e18042 monitor-manager/xrandr: Allow configuring scales on X11 too
This commit makes it possible to configure logical monitor scale also
when running on top of an X11 server using Xrandr. An extra property
'requires-globla-scale' is added to the D-Bus API is added to instruct
a configuration application to only allow setting a global logical
monitor scale.

This is needed to let gsd-xsettings use the configured state to set a
XSettings state that respects the explicit monitor configuration.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Jonas Ådahl
2718699ccc backend: Move settings into a new MetaSettings object
Introduce MetaSettings and add the settings managed by MetaBackend into
the new object. These settings include: experimental-features and UI
scaling factor.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-05-26 14:31:48 +08:00
Marco Trevisan (Treviño)
183f4b0c13 MetaMonitorManager: ignore hotplug_mode_update at startup
hotplug_mode_update is used (mostly by VMs nowadays, and
VMware has implemented it) to inform that modes list (including
the preferred one) might change after an uevent.

However, when using MetaMonitorConfigManager we should
ignore this value at initialization level, or mutter
won't restore the configured values at startup.

https://bugzilla.gnome.org/show_bug.cgi?id=783073
2017-05-25 16:50:29 +08:00
Rui Matos
612432ac3e monitor-manager: Fix format-security gcc warnings 2017-04-12 16:53:30 +02:00
Jonas Ådahl
c214eb15bf monitor-manager: Check active monitors when looking for logical monitor
An inactive monitor will not be assigned to a logical monitor, so don't
try to match against those. This avoids a dereferencing a NULL when the
main output of an inactive monitor doesn't have an assigned CRTC.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 23:53:51 +08:00
Jonas Ådahl
de61da16ae monitor-manager: Reconfigure when 'scale-monitor-framebuffer' is toggled
When the experimental feature 'scale-monitor-framebuffer' is enabled or
disabled, reconfigure the monitors.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:51 +08:00
Jonas Ådahl
bdcb395b33 DisplayConfig: Add 'supports-changing-layout-mode' property
This property may be used by a client to determine whether it is
allowed to change the layout mode.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:51 +08:00
Jonas Ådahl
1caa7f7627 monitor-manager: Add public API to get logical monitor from connector
This adds a function to be used by gnome-shell to get the logical
monitor given a connector name. For now, use the same index integer
method to reference a logical monitor, but this should be revisited by
providing a better API later.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:51 +08:00
Jonas Ådahl
15dd23a323 monitor-manager: Fix gtk-doc of .._get_monitor_for_output
https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:51 +08:00
Jonas Ådahl
04d7fcf60d DisplayConfig: Add display-name monitor property
This is the same property as the one associated with an output in
GetResources.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
9755cd469c DisplayConfig: Make naming convention consistent
Always use hyphens as delimit words in property keys. Underscore to
delimit words in method arguments.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
1bdadfa3e1 backend: Add API to get UI scaling
The UI scaling depends on whether the framebuffers are scaled. Enable
the caller to determine the what scale its UI should be drawn in, in
relation to the stage coordinate space by calling this function. A new
singal "ui-scaling-factor-changed" is added in order to liston for for
changes.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
6c8b103a7b DisplayConfig: Add "is_builtin" monitor property
Add a per-monitor property allowing the application to determine
whether the monitor is builtin or not, e.g. a laptop panel.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
95d0117784 monitor-manager: Hook up config manager to display config confirmation
Make it possible to confirm or cancel the new configuration also when
the new API is used.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
af4017de49 monitor-manager: Derive logical monitor position from top left CRTC
Derive the logical monitor position not by looking at the main output
(the (0, 0) tile), but the one that is placed on the top-left corner.
This might be the non-main output on certain transformations.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:50 +08:00
Jonas Ådahl
0ac2eba4d3 DisplayConfig: Add logical monitor transforms
Add the transform as a logical monitor parameter, both when getting the
current state and applying a new configuration. The transform is defined
to be identical to MetaMonitorTransform.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00
Jonas Ådahl
472a434212 monitor-config-manager: Support logical monitor transforms
Add support for rotated monitors. This is done per logical monitor, as
every monitor assigned to a logical monitor must be transformed in the
same way. This includes being transformed on the same level; e.g. if
the backend does not support transforming any monitor of a logical
monitor natively, then all monitors will be transformed using the
offscreen intermediate framebuffer.

https://bugzilla.gnome.org/show_bug.cgi?id=777732
2017-04-07 22:30:49 +08:00