The brightness is about the vignette. Add a 'vignette_' prefix in order
to give more context. Keep the property name as it is, doing so we don't
break any plugin (e.g., gnome-shell).
https://bugzilla.gnome.org/show_bug.cgi?id=786618
Add the word 'vignette' in order to give some context on what the
snippets do. This will be useful later when we land other snippets
for the gradient effect.
https://bugzilla.gnome.org/show_bug.cgi?id=786618
The reverted commit seems to cause
https://bugzilla.gnome.org/show_bug.cgi?id=787240 for some reason. Lets
be safe and revert it for now, as the code freeze is just around the
corner.
This partly (it doesn't reintroduce a whitespace issue) reverts commit
dbc63430d8.
When cleaning up the display name string management, the display name
string retrieved from libwayland-server was also passed to free() on
clean up. This is invalid as the display name string ownership is not
transferred to us. Fix this by strdup:ing the string before saving it.
https://bugzilla.gnome.org/show_bug.cgi?id=730551
Give clients (such as Xwayland) a chance to bind the wl_output global
before we continue, otherwise there is an significant risk that mutter
won't see the bind request until after the next hot plug which might
have destroyed the global object.
https://bugzilla.gnome.org/show_bug.cgi?id=730551
This avoids updating state (such as position, size etc) when going
headless. Eventually, when non-headless, things will be updated again,
and not until then will we be able to update to a valid state.
https://bugzilla.gnome.org/show_bug.cgi?id=730551
In order to give the clients the best chance to bind the wl_output
before we later remove it (for example on fast hot plugs or in the test
suite), flush the client sockets after creating the global.
https://bugzilla.gnome.org/show_bug.cgi?id=730551
The foreach CRTC monitor mode helper incorrectly iterated over outputs
without CRTC when non-tiled modes were set on tiled monitors. This was
not expected by callers, so fix the helper to only iterate over active
outputs (that has or should have a CRTC).
The test cases uses the incorrect behaviour of the foreach CRTC helper
to check that the disabled outputs mode are set to NULL, so add a
foreach output helper and change the tests to use that instead.
https://bugzilla.gnome.org/show_bug.cgi?id=730551
If there are no active logical monitors, don't try to dereference a
NULL one to get a preferred output winsys id. Instead just set an
invalid one.
https://bugzilla.gnome.org/show_bug.cgi?id=730551
When headless, we don't have any logical monitors to derive a screen
size from, but we can't set it to empty as that will cause issues with
the clutter stage, UI widget layout and other things. To avoid such
issues, just fall back to a 640 x 480 screen size when headless.
https://bugzilla.gnome.org/show_bug.cgi?id=730551
Due to rounding issues, we can't assume a floating point calculation
will end up on an integer, even if we got the factor from the reverse
calculation. Thus, to avoid casting away values like N.999... to N,
when they should really be N+1, round the resulting floating point
calculation before casting it to int.
This fixes an issue where using the scale ~1.739 on a 1920x1080 mode
resulted in error when setting the mode, as the calculated size of the
framebuffer was only 1919x1080.
https://bugzilla.gnome.org/show_bug.cgi?id=786918
When a screen cast session is stand-alone, i.e. not created given a
remote desktop session managing it, allow calling the Start/Stop
methods to start and stop it.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
As of commit 5f5ef3de2cdc816dab82cb7eb5d7171bee0ad2c5 in pipewire the
stream creator can find out the node ID of the stream it created.
So instead of using a special purpose entry to the info property box to
let the application discover stream by monitoring added nodes searching
for the given special purpose entry, just pass the node directly.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
When the PipeWire context or stream ends up in an error state, signal
that the source has closed. This then triggers the stream and finally
the session to be closed too.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
This commit adds basic screen casting and remote desktoping
functionalty. This works by exposing two D-Bus API services:
org.gnome.Mutter.ScreenCast and org.gnome.Mutter.RemoteDesktop.
The remote desktop API is used to create remote desktop sessions. For
each session, a D-Bus object is created, and an application can manage
the session by sending messages to the session object. A remote desktop
session the user to emit input events using the D-Bus methods on the
session object. To get framebuffer content, the application should
create an associated screen cast session.
The screen cast API is used to create screen cast sessions. One can so
far either create stand-alone screen cast sessions, or a screen cast
session associated with a remote desktop session. A remote desktop
associated screen cast session is managed by the remote desktop session.
So far only remote desktop managed screen cast sessions are implemented.
Each screen cast session may have one or more streams. A screen cast
stream is a stream of buffers of some part of the compositor content.
So far API exists for creating streams of monitors and windows, but
only monitor streams are implemented.
When a screen cast session is started, the one PipeWire stream is
created for each screen cast stream created for the session. When this
has happened, a PipeWireStreamAdded signal is emitted on the stream
object, passing a unique identifier. The application may use this
identifier to find the associated stream being advertised by the
PipeWire daemon.
The remote desktop and screen cast functionality must be explicitly be
enabled at ./configure time by passing --enable-remote-desktop to
./configure. Doing this will build both screen cast and remote desktop
support.
To actually enable the screen casting and remote desktop, the user must
enable the experimental feature. See
org.gnome.mutter.experimental-features.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
Add MetaFraction, which consists of two integers, the numerator an the
denominator. The utility function to convert a double to a MetaFraction
comes from gstreamer.
https://bugzilla.gnome.org/show_bug.cgi?id=784199
When monitors changed, previous monitor instances are defunct, and any
reference holder should drop its reference. Sometimes they will want to
continue having a reference to the same monitor, so add this function
to make it possible to find it.
Currently the output and crtc references are invalid, as they are not
yet reference counted, so this can only look at cached fields.
https://bugzilla.gnome.org/show_bug.cgi?id=784199